R1 Floor heating system components
R1 Floor heating system components
 


System surface suitable for cement- and flow screeds.
Orthogonal and diagonal laying with optimal
adjustment on the room-geometry and minimum scrap,
optimal control of laying distances,
with height- and distance-fixed pipe holder,
with humidity separation and
sound-avoidance through
overlapping deep-drawing foil technology,
orthogonal laying with distances:
5,5 - 11 - 16,5 - 22 - 27,5 - 33 cm
Diagonal laying with distances:
7,5 - 15 - 22,5 - 30 cm.


 

Fonterra-Knob panel 30-2,
12 mm,
including impact sound insulation
and 30 mm thermal insulation WLG 040,
suitable for the individual laying
of Fonterra 12 mm-polybutene-pipes,
with additional labyrinth seal
overlapping region,

modelorder detailspacking unitorder code
 length x width  
12301363 x 923 x 12  9,28m²608 491

 

Fonterra-Knob plate ND 11,
12 mm,
including 11 mm thermal insulation WLG 035,
suitable for the individual laying
of Fonterra 12 mm-polybutene-pipes,
with additional labyrinth seal
in overlapping region,

modelorder detailspacking unitorder code
 length x width  
12311363 x 923 x 12  9,28m²608 507

 

Fonterra-Knob plate smart,
12 mm,
for on-site thermal insulation,
suitable for individual laying
of Fonterra 12 mm-polybutene-pipes,
with additional labyrinth seal
in overlapping region,

modelorder detailspacking unitorder code
 length x width  
12321363 x 923 x 12  9,28m²608 514

 
 
 

Fonterra-Distribution door set 30-2,
12 mm,
with two distribution foils
and 12 door elements,
including compensating insulation,

modelorder detailspacking unitorder code
 s  
1230.112  6,00m²609 252

 

Fonterra-Distribution door set ND 11,
12 mm,
with two distribution foils
and 12 door elements,
including compensating insulation,

modelorder detailspacking unitorder code
 s  
1231.112  6,00m²609 269

 

Fonterra-Distribution door set smart,
12 mm,
with two distribution foils
and 12 door elements,
for on-site insulation,

modelorder detailspacking unitorder code
 s  
1232.112  6,00m²609 276

 
 
 

Fonterra-PB-Pipe,
for area temperation,
oxygen seal in accordance
with DIN 4726,
in 240 m coils,
modelorder detailspacking unitorder code
 da x s  
140512 x 1,3  240m615 680

in 650 m coils,
modelorder detailspacking unitorder code
 da x s  
1405.112 x 1,3  650m616 502

 
 
 

Fonterra-Union,
for the connection of Fonterra pipes
to heating manifolds with european cone,

modelorder detailspacking unitorder code
 d x G  
103712 x 3/4  10614 508

 

Fonterra-Union,
with SC-Contur,
dull nickel-plated,
for connection of Fonterra pipes
at heating circuit manifolds with
Euro cone 3/4",
with press end,

modelorder detailspacking unitorder code
 d x G  
123612 x 3/4  10614 584

 

Fonterra-Coupling,
for connection of Fonterra pipes,

modelorder detailspacking unitorder code
 d  
1030.512  5614 669

 

Fonterra-Coupling,
with SC-Contur,
for connection of Fonterra pipes,

modelorder detailspacking unitorder code
 d  
122312  5614 676

 

Fonterra-Adapter,
with SC-Contur,
male,

modelorder detailspacking unitorder code
 d x R  
1213.512 x 1/2  5636 166

 

Fonterra-Plug-in piece,
with SC-Contur,
for press connection of
Fonterra PB-Pipes to Sanpress-,
Sanpress INOX- and Profipress-fittings,

modelorder detailspacking unitorder code
 d x d  
121312 x 15  10637 002

 
 
 

Fonterra-Plate dowel,
for Fronterra Base-knob panels
without sound insulation,
for connecting the foil elements
with insulation installed on side,

modelorder detailspacking unitorder code
 &durchmesser; x L x &durchmesser;  
148035 x 25 x 5  100569 037

 

Fonterra-Edge insulation strip 150/8,
made of pe foam,
for cement floor screed
in accordance DIN 18560,
building material class B2,
cfc-free,
25 m in coils,

modelorder detailspacking unitorder code
1270200m609 474

 

Fonterra-Edge insulation strip 150/10,
self-adhesive,
made of PE-foam,
for flow- and cement floor screed,
in accordance with DIN 18560,
perforated,
building material class B2,
CFC-free,
25 m in coils,

modelorder detailspacking unitorder code
1270.1200m609 481

 

Fonterra-Pipe guiding elbow 90°,
to divert the Fonterra-Pipes,

modelorder detailspacking unitorder code
 for pipe-&durchmesser;  
127212&bindestrichlang;17  50609 498

 

Fonterra-Movement joint protection 12,
for protection of
Fonterra 12 mm-polybutene-pipes
in joint area,
self-adhesive tape,
in 25 m coils,

modelorder detailspacking unitorder code
 thickness x width  
127350 x 3  25 / 250m609 511

 

Fonterra-Expansion joint profile 10/80,
with adhesive foot,
for an safety screed interruption
and formation of expansion joints,
with PE-core,
dimensionally stable,
construction material class B2,

modelorder detailspacking unitorder code
 length  
12751800  18m609 542

 

Fonterra-Round profile,
for clamping the edge insulation strip
and lining of expansion joints in
Fonterra-Knob plates,
in 25 m coils,

modelorder detailspacking unitorder code
 &durchmesser;  
127415  25m609 535

 

Fonterra-Plastic dowls,
for safety fixation of Fonterra-
Knob plates on solid grounds,

modelorder detailspacking unitorder code
 length  
128175  20609 719
135  20609 726

 

Fonterra-Utility knife,
to cut the EPS-
and PUR insulation plates,

modelorder detailspacking unitorder code
1219.8625 207

 

Fonterra-Spare blade,
for utility knife,
10 pcs. in the dispencer,

modelorder detailspacking unitorder code
1219.9625 214

 
 
 





 

Fonterra-Knob plate 30-2,
15 mm,
including impact sound insulation
and 30 mm thermal insulation WLG 040,
suitable for individual laying
of Fonterra 15 mm-pipes,
wtih additional labyrinth seal
in overlapping area,

modelorder detailspacking unitorder code
 length x width  
12401363 x 923 x 15  9,28m²608 521

 

Fonterra-Knob plate ND 11,
15 mm,
including 11 mm thermal insulation WLG 035,
suitable for individual laying
of Fonterra 15 mm-pipes,
with additional labyrinth seal
in overlapping area,

modelorder detailspacking unitorder code
 length x width  
12411363 x 923 x 15  9,28m²608 538

 

Fonterra-Knob plate smart,
15 mm,
for on-site thermal insulation,
suitable for individual laying
of Fonterra 15 mm-pipes,
with additional labyrinth seal
in overlapping area,

modelorder detailspacking unitorder code
 length x width  
12421363 x 923 x 15  9,28m²608 545

 
 
 

Fonterra-Distribution door set 30-2,
15 mm,
with two distribution foils
and 12 door elements,
including compensating insulation,

modelorder detailspacking unitorder code
 s  
1240.115  6,00m²609 283

 

Fonterra-Distribution door set ND 11,
15 mm,
with two distribution foils
and 12 door elements,
including compensating insulation,

modelorder detailspacking unitorder code
 s  
1241.115  6,00m²609 290

 

Fonterra-Distribution door set smart,
15 mm,
with two distribution foils
and 12 door elements,
for on-site insulation,

modelorder detailspacking unitorder code
 s  
1242.115  6,00m²609 306

 
 
 

Fonterra-PB-Pipe,
for area temperation,
oxygen seal in accordance
with DIN 4726,
in 240 m coils,
modelorder detailspacking unitorder code
 da x s  
140515 x 1,5  240m616 519

in 650 m coils,
modelorder detailspacking unitorder code
 da x s  
1405.215 x 1,5  650m616 526

 
 
 

Fonterra-Union,
for the connection of Fonterra pipes
to heating manifolds with european cone,

modelorder detailspacking unitorder code
 d x G  
103715 x 3/4  10615 796

 

Fonterra-Union,
with SC-Contur,
dull nickel-plated,
for connection of Fonterra pipes
at heating circuit manifolds with
Euro cone 3/4",
with press end,

modelorder detailspacking unitorder code
 d x G  
123615 x 3/4  10614 591

 

Fonterra-Coupling,
for connection of Fonterra pipes,

modelorder detailspacking unitorder code
 d  
1030.515  5615 789

 

Fonterra-Coupling,
with SC-Contur,
for connection of Fonterra pipes,

modelorder detailspacking unitorder code
 d  
122315  5614 683

 

Fonterra-Adapter,
with SC-Contur,
male,

modelorder detailspacking unitorder code
 d x R  
1213.515 x 1/2  5636 173

 

Fonterra-Plug-in piece,
with SC-Contur,
for press connection of
Fonterra PB-Pipes to Sanpress-,
Sanpress INOX- and Profipress-fittings,

modelorder detailspacking unitorder code
 d x d  
121315 x 15  10636 999

 
 
 

Fonterra-Plate dowel,
for Fronterra Base-knob panels
without sound insulation,
for connecting the foil elements
with insulation installed on side,

modelorder detailspacking unitorder code
 &durchmesser; x L x &durchmesser;  
148035 x 25 x 5  100569 037

 

Fonterra-Edge insulation strip 150/8,
made of pe foam,
for cement floor screed
in accordance DIN 18560,
building material class B2,
cfc-free,
25 m in coils,

modelorder detailspacking unitorder code
1270200m609 474

 

Fonterra-Edge insulation strip 150/10,
self-adhesive,
made of PE-foam,
for flow- and cement floor screed,
in accordance with DIN 18560,
perforated,
building material class B2,
CFC-free,
25 m in coils,

modelorder detailspacking unitorder code
1270.1200m609 481

 

Fonterra-Pipe guiding elbow 90°,
to divert the Fonterra-Pipes,

modelorder detailspacking unitorder code
 for pipe-&durchmesser;  
127212&bindestrichlang;17  50609 498

 

Fonterra-Expansion protective pipe,
for the protection of Fonterra pipes
in the expansion joints,
made of PE, black,
50 m in coils,

modelorder detailspacking unitorder code
 for plastic-pipe
x protective tube-outside-&durchmesser;
  
1404(17) 25  50m610 708

 

Fonterra-Expansion joint profile 10/80,
with adhesive foot,
for an safety screed interruption
and formation of expansion joints,
with PE-core,
dimensionally stable,
construction material class B2,

modelorder detailspacking unitorder code
 length  
12751800  18m609 542

 

Fonterra-Round profile,
for clamping the edge insulation strip
and lining of expansion joints in
Fonterra-Knob plates,
in 25 m coils,

modelorder detailspacking unitorder code
 &durchmesser;  
127415  25m609 535

 

Fonterra-Plastic dowls,
for safety fixation of Fonterra-
Knob plates on solid grounds,

modelorder detailspacking unitorder code
 length  
128175  20609 719
135  20609 726

 

Fonterra-Utility knife,
to cut the EPS-
and PUR insulation plates,

modelorder detailspacking unitorder code
1219.8625 207

 

Fonterra-Spare blade,
for utility knife,
10 pcs. in the dispencer,

modelorder detailspacking unitorder code
1219.9625 214

 
 
 

Fonterra Reno-Grundplatte,
Gipsfaserplatte 18 mm,
mit gefrästen Rohrführungsnuten
zur bauseitigen Integration des
Fonterra 12 mm-Polybuten-Rohres,
geeignet für Betriebstemperaturen
bis max. 50 °C,

modelorder detailspacking unitorder code
 L x B  
1238.101000 x 620  30657 437

 

Fonterra Reno-Kopfplatte,
Gipsfaserplatte 18 mm,
mit gefrästen Rohrführungsnuten
zur bauseitigen Integration des
Fonterra 12 mm-Polybuten-Rohres,
geeignet für Betriebstemperaturen
bis max. 50 °C,

modelorder detailspacking unitorder code
 L x B  
1238.11620 x 310  30657 420

 

Fonterra-Plaster board,
18 mm, unmilled,
for residual surfaces,

modelorder detailspacking unitorder code
 length x width  
1238.21000 x 620 x 18  30615 567

 
 
 

Fonterra-PB-Pipe,
for area temperation,
oxygen seal in accordance
with DIN 4726,
in 240 m coils,
modelorder detailspacking unitorder code
 da x s  
140512 x 1,3  240m615 680

in 650 m coils,
modelorder detailspacking unitorder code
 da x s  
1405.112 x 1,3  650m616 502

 
 
 

Fonterra-Union,
for the connection of Fonterra pipes
to heating manifolds with european cone,

modelorder detailspacking unitorder code
 d x G  
103712 x 3/4  10614 508

 

Fonterra-Union,
with SC-Contur,
dull nickel-plated,
for connection of Fonterra pipes
at heating circuit manifolds with
Euro cone 3/4",
with press end,

modelorder detailspacking unitorder code
 d x G  
123612 x 3/4  10614 584

 

Fonterra-Coupling,
for connection of Fonterra pipes,

modelorder detailspacking unitorder code
 d  
1030.512  5614 669

 

Fonterra-Coupling,
with SC-Contur,
for connection of Fonterra pipes,

modelorder detailspacking unitorder code
 d  
122312  5614 676

 

Fonterra-Plug-in piece,
with SC-Contur,
for press connection of
Fonterra PB-Pipes to Sanpress-,
Sanpress INOX- and Profipress-fittings,

modelorder detailspacking unitorder code
 d x d  
121312 x 15  10637 002

 
 
 

Fonterra-Edge insulation strip 150/8,
made of pe foam,
for cement floor screed
in accordance DIN 18560,
building material class B2,
cfc-free,
25 m in coils,

modelorder detailspacking unitorder code
1270200m609 474

 

Fonterra-Edge insulation strip 150/10,
self-adhesive,
made of PE-foam,
for flow- and cement floor screed,
in accordance with DIN 18560,
perforated,
building material class B2,
CFC-free,
25 m in coils,

modelorder detailspacking unitorder code
1270.1200m609 481

 

Fonterra-Pipe guiding elbow 90°,
to divert the Fonterra-Pipes,

modelorder detailspacking unitorder code
 for pipe-&durchmesser;  
127212&bindestrichlang;17  50609 498

 

Fonterra-Movement joint protection 12,
for protection of
Fonterra 12 mm-polybutene-pipes
in joint area,
self-adhesive tape,
in 25 m coils,

modelorder detailspacking unitorder code
 thickness x width  
127350 x 3  25 / 250m609 511

 

Fonterra-Expansion joint profile 10/80,
with adhesive foot,
for an safety screed interruption
and formation of expansion joints,
with PE-core,
dimensionally stable,
construction material class B2,

modelorder detailspacking unitorder code
 length  
12751800  18m609 542

 

Fonterra-Dry wall screw,
for fixation Fonterrra-Plaster board
on the substructure,
or Reno-Plaster board
with dry screed plates,

modelorder detailspacking unitorder code
 length  
125925  1000615 574

 

Fonterra-Floor pavement adhesive,
for Reno-Plaster borads,
for extensively glueing
Reno-System plates with
dry screed plates,

modelorder detailspacking unitorder code
 kg  
1237.4624 903

 
 
 

Fonterra Reno XL-Basic plate,
with milled bend degree supports
for on-site integration
of Fonterra 12 mm-polybutene-pipe,

modelorder detailspacking unitorder code
 length x width  
12351130 x 565  25655 488

 

Fonterra Reno XL-Top plate,
with milled bend degree supports
for on-site integration
of Fonterra 12 mm-polybutene-pipe,

modelorder detailspacking unitorder code
 length x width  
1235.11130 x 565  25655 495

 
 
 

Fonterra-PB-Pipe,
for area temperation,
oxygen seal in accordance
with DIN 4726,
in 240 m coils,
modelorder detailspacking unitorder code
 da x s  
140512 x 1,3  240m615 680

in 650 m coils,
modelorder detailspacking unitorder code
 da x s  
1405.112 x 1,3  650m616 502

 
 
 

Fonterra-Union,
for the connection of Fonterra pipes
to heating manifolds with european cone,

modelorder detailspacking unitorder code
 d x G  
103712 x 3/4  10614 508

 

Fonterra-Union,
with SC-Contur,
dull nickel-plated,
for connection of Fonterra pipes
at heating circuit manifolds with
Euro cone 3/4",
with press end,

modelorder detailspacking unitorder code
 d x G  
123612 x 3/4  10614 584

 

Fonterra-Coupling,
with SC-Contur,
for connection of Fonterra pipes,

modelorder detailspacking unitorder code
 d  
122312  5614 676

 

Fonterra-Plug-in piece,
with SC-Contur,
for press connection of
Fonterra PB-Pipes to Sanpress-,
Sanpress INOX- and Profipress-fittings,

modelorder detailspacking unitorder code
 d x d  
121312 x 15  10637 002

 
 
 

Fonterra-Edge insulation strip 150/10,
self-adhesive,
made of PE-foam,
for flow- and cement floor screed,
in accordance with DIN 18560,
perforated,
building material class B2,
CFC-free,
25 m in coils,

modelorder detailspacking unitorder code
1270.1200m609 481

 

Fonterra-Pipe guiding elbow 90°,
to divert the Fonterra-Pipes,

modelorder detailspacking unitorder code
 for pipe-&durchmesser;  
127212&bindestrichlang;17  50609 498

 

Fonterra-Expansion joint profile 10/80,
with adhesive foot,
for an safety screed interruption
and formation of expansion joints,
with PE-core,
dimensionally stable,
construction material class B2,

modelorder detailspacking unitorder code
 length  
12751800  18m609 542

 
 
 

Fonterra-Panel heating,
consisting of:
Plaster board 18 mm,
with integrated Fonterra 12 mm-polybutene-pipes,
oxygen seal in accordance with DIN 4726,
suitable for working temperatures up to
max. 50 °C,

modelorder detailspacking unitorder code
 length x width  
12372000 x 310  30615 642

 

Fonterra-Panel heating,
consisting of:
Plaster board 18 mm,
with integrated Fonterra 12 mm polybutene-pipes,
with 70% and 100% active heating surface,
oxygen seal in accordance with DIN 4726,
suitable for working temperatures up to
max. 50 °C,

modelorder detailspacking unitorder code
 length x width  
1237.11000 x 620 (70%)  30615 659
1000 x 620 (100%)  30615 666

 

Fonterra-Plaster board,
18 mm,
without polybutene pipes,
for remaining surfaces,

modelorder detailspacking unitorder code
 length x width  
1237.22000 x 620 x 18  30615 673

 
 
 

Fonterra-PB-Pipe,
for area temperation,
oxygen seal in accordance
with DIN 4726,
in 240 m coils,
modelorder detailspacking unitorder code
 da x s  
140512 x 1,3  240m615 680

in 650 m coils,
modelorder detailspacking unitorder code
 da x s  
1405.112 x 1,3  650m616 502

 

Fonterra-PB-pipe,
for the combination of floor
heating systems and radiators,
max. working temperature 70°C,
internal pipe 12 mm in corrugated pipe 21 mm,

modelorder detailspacking unitorder code
 d  
120312  120m609 658

 
 
 

Fonterra-Union,
for the connection of Fonterra pipes
to heating manifolds with european cone,

modelorder detailspacking unitorder code
 d x G  
103712 x 3/4  10614 508

 

Fonterra-Union,
with SC-Contur,
dull nickel-plated,
for connection of Fonterra pipes
at heating circuit manifolds with
Euro cone 3/4",
with press end,

modelorder detailspacking unitorder code
 d x G  
123612 x 3/4  10614 584

 

Fonterra-Coupling,
for connection of Fonterra pipes,

modelorder detailspacking unitorder code
 d  
1030.512  5614 669

 

Fonterra-Coupling,
with SC-Contur,
for connection of Fonterra pipes,

modelorder detailspacking unitorder code
 d  
122312  5614 676

 

Fonterra-Adapter,
with SC-Contur,
male,

modelorder detailspacking unitorder code
 d x R  
1213.512 x 1/2  5636 166

 

Fonterra-Plug-in piece,
with SC-Contur,
for press connection of
Fonterra PB-Pipes to Sanpress-,
Sanpress INOX- and Profipress-fittings,

modelorder detailspacking unitorder code
 d x d  
121312 x 15  10637 002

 
 
 

Fonterra-Pipe guiding elbow 90°,
to divert the Fonterra-Pipes,

modelorder detailspacking unitorder code
 for pipe-&durchmesser;  
127212&bindestrichlang;17  50609 498

 

Fonterra-Movement joint protection 12,
for protection of
Fonterra 12 mm-polybutene-pipes
in joint area,
self-adhesive tape,
in 25 m coils,

modelorder detailspacking unitorder code
 thickness x width  
127350 x 3  25 / 250m609 511

 

Fonterra-Dry wall screw,
for fixation Fonterrra-Plaster board
on the substructure,
or Reno-Plaster board
with dry screed plates,

modelorder detailspacking unitorder code
 length  
125945  1000625 184

 

Fonterra-Joint adhesive,
for adhesive wall heating-
and cooling ceiling-plates,
in cartridges,
content 310 g,
for approx. 15 consecutive meter,

modelorder detailspacking unitorder code
 g  
1237.3310  624 897

 

Fonterra-Temperature foil,
to find the polybutene-
wall heating pipes concealed
and in dry construction systems,
multiple using,

modelorder detailspacking unitorder code
 length x width  
1237.5160 x 70  624 910

 
 
 

Fonterra-PB-Pipe,
for area temperation,
oxygen seal in accordance
with DIN 4726,
in 240 m coils,
modelorder detailspacking unitorder code
 da x s  
140512 x 1,3  240m615 680

in 650 m coils,
modelorder detailspacking unitorder code
 da x s  
1405.112 x 1,3  650m616 502

 

Fonterra-PB-pipe,
for the combination of floor
heating systems and radiators,
max. working temperature 70°C,
internal pipe 12 mm in corrugated pipe 21 mm,

modelorder detailspacking unitorder code
 d  
120312  120m609 658

 
 
 

Fonterra-Union,
for the connection of Fonterra pipes
to heating manifolds with european cone,

modelorder detailspacking unitorder code
 d x G  
103712 x 3/4  10614 508

 

Fonterra-Union,
with SC-Contur,
dull nickel-plated,
for connection of Fonterra pipes
at heating circuit manifolds with
Euro cone 3/4",
with press end,

modelorder detailspacking unitorder code
 d x G  
123612 x 3/4  10614 584

 

Fonterra-Coupling,
for connection of Fonterra pipes,

modelorder detailspacking unitorder code
 d  
1030.512  5614 669

 

Fonterra-Coupling,
with SC-Contur,
for connection of Fonterra pipes,

modelorder detailspacking unitorder code
 d  
122312  5614 676

 

Fonterra-Adapter,
with SC-Contur,
male,

modelorder detailspacking unitorder code
 d x R  
1213.512 x 1/2  5636 166

 

Fonterra-Plug-in piece,
with SC-Contur,
for press connection of
Fonterra PB-Pipes to Sanpress-,
Sanpress INOX- and Profipress-fittings,

modelorder detailspacking unitorder code
 d x d  
121312 x 15  10637 002

 
 
 

Fonterra-Clamping rail,
for safety fiaxation of
Fonterra-pipes at on-site insulation,
pipe distance 25 mm,
2 m long,

modelorder detailspacking unitorder code
 for pipe-&durchmesser;  
123412 x 2000  20m609 429

 

Fonterra-Pipe guiding elbow 90°,
to divert the Fonterra-Pipes,

modelorder detailspacking unitorder code
 for pipe-&durchmesser;  
127212&bindestrichlang;17  50609 498

 

Fonterra-Movement joint protection 12,
for protection of
Fonterra 12 mm-polybutene-pipes
in joint area,
self-adhesive tape,
in 25 m coils,

modelorder detailspacking unitorder code
 thickness x width  
127350 x 3  25 / 250m609 511

 

Fonterra-Nail round clip,
for fixation of
Fonterra 12 mm-polybutene-pipe
on brick walls,

modelorder detailspacking unitorder code
1239.4100615 611

 

Fonterra-Percussion dowl,
for fixation of wall clamping bar
on concrete and limestone-walls,

modelorder detailspacking unitorder code
 length x &durchmesser;  
1239.235 x 6  200615 598

 

Fonterra-Window screw,
for fixation of wall clamping bars
on poroton-brick walls,
suitable without dowl,

modelorder detailspacking unitorder code
 length  
1259.122  1000625 191

 

Fonterra-Temperature foil,
to find the polybutene-
wall heating pipes concealed
and in dry construction systems,
multiple using,

modelorder detailspacking unitorder code
 length x width  
1237.5160 x 70  624 910

 
 
 

Fonterra-Ceiling cooling plate,
consisting of:
Plaster board 18 mm,
with integrated
Fonterra 12 mm-polybutene-pipes,
oxygen seal in accordance with DIN 4726,
suitable for working temperatures up to
maximum 50 °C,

modelorder detailspacking unitorder code
 length x width  
1220.12000 x 310  636 746
1000 x 620  30636 760
2000 x 620  636 753

 

Fonterra-Plaster board,
18 mm,
without polybutene pipes,
for remaining surfaces,

modelorder detailspacking unitorder code
 length x width  
1237.22000 x 620 x 18  30615 673

 
 
 

Fonterra-PB-Pipe,
for area temperation,
oxygen seal in accordance
with DIN 4726,
in 240 m coils,
modelorder detailspacking unitorder code
 da x s  
140512 x 1,3  240m615 680

in 650 m coils,
modelorder detailspacking unitorder code
 da x s  
1405.112 x 1,3  650m616 502

 
 
 

Fonterra-Union,
for the connection of Fonterra pipes
to heating manifolds with european cone,

modelorder detailspacking unitorder code
 d x G  
103712 x 3/4  10614 508

 

Fonterra-Union,
with SC-Contur,
dull nickel-plated,
for connection of Fonterra pipes
at heating circuit manifolds with
Euro cone 3/4",
with press end,

modelorder detailspacking unitorder code
 d x G  
123612 x 3/4  10614 584

 

Fonterra-Coupling,
for connection of Fonterra pipes,

modelorder detailspacking unitorder code
 d  
1030.512  5614 669

 

Fonterra-Coupling,
with SC-Contur,
for connection of Fonterra pipes,

modelorder detailspacking unitorder code
 d  
122312  5614 676

 

Fonterra-Adapter,
with SC-Contur,
male,

modelorder detailspacking unitorder code
 d x R  
1213.512 x 1/2  5636 166

 

Fonterra-Plug-in piece,
with SC-Contur,
for press connection of
Fonterra PB-Pipes to Sanpress-,
Sanpress INOX- and Profipress-fittings,

modelorder detailspacking unitorder code
 d x d  
121312 x 15  10637 002

 
 
 

Fonterra-Joint adhesive,
for adhesive wall heating-
and cooling ceiling-plates,
in cartridges,
content 310 g,
for approx. 15 consecutive meter,

modelorder detailspacking unitorder code
 g  
1237.3310  624 897

 

Fonterra-Pipe guiding elbow 90°,
to divert the Fonterra-Pipes,

modelorder detailspacking unitorder code
 for pipe-&durchmesser;  
127212&bindestrichlang;17  50609 498

 

Fonterra-Expansion protective pipe,
for the protection of Fonterra pipes
in the expansion joints,
made of PE, black,
50 m in coils,

modelorder detailspacking unitorder code
 for plastic-pipe
x protective tube-outside-&durchmesser;
  
1404(17) 25  50m610 708

 
 
 


Viega Fonterra-Tacker plate
System surface made of quality controlled,
CFC-free polystyrene foam (EPS-DES;
application type DIN 4108-10)
as heat- and impact sound insulation,
including tear strength,
waterproof and one-sided overlapping
fabric-reinforced coating
with imprinted laying-grid.
all-over glued in accordance
with DIN EN 13163,
system-performance tested in accordance
with DIN EN 1264.
Laying in distances:
5,5 - 11 - 16,5 - 22 - 27,5 - 33 cm,


 

Fonterra-Folded tacker plate EPS,
including impact sound- and heat insulation,
concealed with tearproof fabric foil,
with 30 mm overlapping,
with printed laying grid,
construction material class B2,
cfc-free,

modelorder detailspacking unitorder code
 s&bindestrichlang;c  
126025&bindestrichlang;2  16,00m²609 351
30&bindestrichlang;2  14,00m²609 368
30&bindestrichlang;3  14,00m²609 375
35&bindestrichlang;3  12,00m²609 382

 

Fonterra-Coil tacker plate EPS,
including impact sound- and heat insulation,
concealed with tearproof fabric foil,
with 30 mm overlapping,
with printed laying grid,
construction material class B2,
cfc-free,

modelorder detailspacking unitorder code
 s&bindestrichlang;c  
126125&bindestrichlang;2  10,00m²609 399
30&bindestrichlang;2  10,00m²613 433
30&bindestrichlang;3  10,00m²609 405
35&bindestrichlang;3  10,00m²609 412

 
 
 

Fonterra-PB-Pipe,
for area temperation,
oxygen seal in accordance
with DIN 4726,
in 240 m coils,
modelorder detailspacking unitorder code
 da x s  
140515 x 1,5  240m616 519

in 650 m coils,
modelorder detailspacking unitorder code
 da x s  
1405.215 x 1,5  650m616 526

 

Fonterra-PE-Xc-pipe,
for the floor heating installation,
oxygen seal
in accordance with DIN 4726,
natural coloured,
240 m in rolls,
modelorder detailspacking unitorder code
 da x s  
140117 x 2,0  240m609 627

in 650 m coils,
modelorder detailspacking unitorder code
 external diameter
x wall thickness
  
1401.517 x 2,0  650m609 641

 

Fonterra-PE-Xc-pipe,
natural coloured,
for the floor heating installation,
oxygen seal in accordance with DIN 4726,

in 240 m coils,
240 m in Ringen,
modelorder detailspacking unitorder code
 external diameter
x wall thickness
  
120420 x 2,0  240m613 631

 

Fonterra-PE-Xc-pipes,
for the floorheating installation,
oxygen seal in accordance with DIN 4726,
nature coloured,

in 240 m coils,

modelorder detailspacking unitorder code
 external diameter
x wall thickness
  
1401.825 x 2,3  240m636 579*
* only available from existing stock

 
 
 

Fonterra-Spreader clip,
yellow,
U-clip to fix the pipe
through a stapler,
magazinised,
displacement for model 1446,

modelorder detailspacking unitorder code
 for pipe-&durchmesser;  
124514&bindestrichlang;20  1120656 966

 

Fonterra-Union,
for the connection of Fonterra pipes
to heating manifolds with european cone,

modelorder detailspacking unitorder code
 d x G  
103715 x 3/4  10615 796
17 x 3/4  10614 539
20 x 3/4  10614 553

 

Fonterra-Union,
with SC-Contur,
dull nickel-plated,
for connection of Fonterra pipes
at heating circuit manifolds with
Euro cone 3/4",
with press end,

modelorder detailspacking unitorder code
 d x G  
123615 x 3/4  10614 591
17 x 3/4  10614 614
20 x 3/4  10614 638

 

Fonterra-Adapter,
with SC-Contur,
male,

modelorder detailspacking unitorder code
 d x R  
1213.515 x 1/2  5636 173
20 x 3/4  5614 652

 

Fonterra-Coupling,
for connection of Fonterra pipes,

modelorder detailspacking unitorder code
 d  
1030.515  5615 789
17  5619 817
20  5619 824
25  5640 996

 

Fonterra-Coupling,
with SC-Contur,
for connection of Fonterra pipes,

modelorder detailspacking unitorder code
 d  
122315  5614 683
17  5614 706
20  5614 720

 

Fonterra-Plug-in piece,
with SC-Contur,
for press connection of
Fonterra PB-Pipes to Sanpress-,
Sanpress INOX- and Profipress-fittings,

modelorder detailspacking unitorder code
 d x d  
121315 x 15  10636 999

 
 
 

Fonterra-EPS-Thermal insulating board,
EPS-insulation, WLG 040,
additional insulation for surface heating,
cfc-free,
1 x 0,5 m,

modelorder detailspacking unitorder code
 thickness  
12821000 x 500 x 20  12,00m²609 214
1000 x 500 x 30  8,00m²609 221

 

Fonterra-PUR-Thermal insulation board,
PUR-insulation, WLG 025,
additional insulation for surface heating,
cfc-free,
coated on both sides,
1,2 x 0,6 m,

modelorder detailspacking unitorder code
 thickness  
128330  11,52m²609 238
40  8,64m²609 245
46  7,20m²609 856
52  7,20m²609 863
60  5,76m²609 870

 
 
 

Fonterra-Edge insulation strip 150/8,
made of pe foam,
for cement floor screed
in accordance DIN 18560,
building material class B2,
cfc-free,
25 m in coils,

modelorder detailspacking unitorder code
1270200m609 474

 

Fonterra-Edge insulation strip 150/10,
self-adhesive,
made of PE-foam,
for flow- and cement floor screed,
in accordance with DIN 18560,
perforated,
building material class B2,
CFC-free,
25 m in coils,

modelorder detailspacking unitorder code
1270.1200m609 481

 

Fonterra-Pipe guiding elbow 90°,
to divert the Fonterra-Pipes,

modelorder detailspacking unitorder code
 for pipe-&durchmesser;  
127212&bindestrichlang;17  50609 498
25  50637 019

 

Fonterra-Expansion protective pipe,
for the protection of Fonterra pipes
in the expansion joints,
made of PE, black,
50 m in coils,

modelorder detailspacking unitorder code
 for plastic-pipe
x protective tube-outside-&durchmesser;
  
1404(17) 25  50m610 708
(20) 28  50m562 731

 

Fonterra-Expansion joint profile 10/80,
with adhesive foot,
for an safety screed interruption
and formation of expansion joints,
with PE-core,
dimensionally stable,
construction material class B2,

modelorder detailspacking unitorder code
 length  
12751800  18m609 542

 

Fonterra-Stapler,
for inserting spreader clips,
suitable for pipe dimensions
from 14-20 mm,
displacement for model 1445,

modelorder detailspacking unitorder code
1445.2659 165

 

Fonterra-Separating sheet,
separating the layers,
between the EPS and
the butimen surfaces,

modelorder detailspacking unitorder code
 thickness  
12840,1  100,00m²609 887

 

Fonterra-Adhesive tape,
to connect the Fonterra-System plates,
66 m in coils,

modelorder detailspacking unitorder code
 width  
127950  6609 672

 

Fonterra-Tape roller,
for plastic adhesive tape,
to tape the Fonterra-System plates,

modelorder detailspacking unitorder code
1280609 702

 

Fonterra-Utility knife,
to cut the EPS-
and PUR insulation plates,

modelorder detailspacking unitorder code
1219.8625 207

 

Fonterra-Spare blade,
for utility knife,
10 pcs. in the dispencer,

modelorder detailspacking unitorder code
1219.9625 214

 
 
 

Fonterra-Manifold station 1",
stainless steel,
with 3/4" euro-cone,
with adjustable spindle,
flat sealing with 1" sleeve nut,
with galvanised mounting rails,
left and right sided connection,
with deaireation and drainage
valve per manifold row,
for Viega actulating drives 24 V
and 230 V,

modelorder detailspacking unitorder code
 manifold outlets  
1006587 741
587 758
587 765
587 772
587 789
587 796
587 802
587 819
10  587 826
11  587 833
12  587 840

 

Fonterra-Extension set,
for heating circuit manifold,
with adjustable spindle,
made of stainless steel,
with mit 3/4" euro cone,
flat sealing with 1" sleeve nut,

modelorder detailspacking unitorder code
1006.2615 772

 

Fonterra-Manifold station 1",
stainless steel,
with 3/4" euro-cone,
with flow quantity gauge,
flat sealing with 1" sleeve nut,
with galvanised mounting rails,
left and right sided connection,
with deaireation and drainage
valve per manifold row,
for Viega actulating drives 24 V
and 230 V,

modelorder detailspacking unitorder code
 manifold outlets  
1004599 560
599 577
599 584
599 591
599 607
599 614
599 621
599 638
10  599 645
11  599 652
12  599 669

 

Fonterra-Extension set,
for heating circuit manifold,
with flow regulator,
made of stainless steel,
with mit 3/4" euro cone,
flat sealing with 1" sleeve nut,

modelorder detailspacking unitorder code
1004.2615 765

 

Fonterra-Industry manifold 1 1/2",
stainless steel,
flat sealing,
with 2" sleeve nut,
left and right sided connection,
with shut-off system,
distance between outlets 80 mm,

modelorder detailspacking unitorder code
 manifold outlets  
1007620 806
620 813
620 820
620 837
620 844
621 957
10  621 964
11  621 971
12  621 988
13  621 995
14  622 008
15  622 015
16  622 022

 

Fonterra-Galvanised assembly console,
including pipe shackles and
sound insulated inlay,
for mounting the Fonterra-
Industry manifold 1 1/2",

modelorder detailspacking unitorder code
1299613 082

 
 
 

Fonterra-Ball valve set,
for Fonterra-Heating circuit manifold 1"
(stainless steel),
nickel plated brass,

modelorder detailspacking unitorder code
 R x G  
10413/4 x 1  606 275
1 x 1  606 268

 

Ball-valve set,
(2 pieces),
made of brass nickel-plated,
for Fonterra-Industrial manifold 1 1/2"
(stainless steel),

modelorder detailspacking unitorder code
1041.1  656 485

 

Fonterra-Zone valve set 1",
passage,
for the zone control of
Fonterrra-manifold station
model 1004 and model 1006,
in connection with actulating drive
model 1248,

modelorder detailspacking unitorder code
1286610 005

 

Fonterra-Differential pressure regulation set 250-1",
for dynamic differential pressure regulation
at the manifold,
with impulse line,
ball valve and union,

modelorder detailspacking unitorder code
1287610 050

 

Fonterra-Heat meter set,
130 x 1" and 110 x 3/4",
with ball-valves,
fitting- and measuring piece 1",
with union,
horizontal,
modelorder detailspacking unitorder code
1288610 074

vertical,
modelorder detailspacking unitorder code
1288.1610 081

 
 
 

Fonterra-Pre-wall manifold cabinet,
white,
for the installation of
Fonterra-Heating circuit manifolds
model 1004 and model 1006,

modelorder detailspacking unitorder code
 type  
1294.1460  610 326
560  610 333
700  610 340
1000  610 357
1200  610 371

 

Fonterra-Concealed manifold cabinet,
white,
for the installation of
Fonterra-Heating circuit manifolds
model 1004 and model 1006,

modelorder detailspacking unitorder code
 type  
1294460  610 272
560  610 289
700  610 296
1000  610 302
1200  610 319

 

Fonterra-Concealed manifold cabinet,
white,
installation depth 80 mm,
for the installation of
Fonterra-Heating circuit manifolds
model 1004 and model 1006,

modelorder detailspacking unitorder code
 type  
1294.2460  636 425
560  636 432
700  636 449
1000  636 555
1200  636 562

 

Fonterra-Wall bracket,
made of galvanized steel,
for the installation of
Fonterra-Heating circuit manifolds
model 1004 and model 1006 into the
concealed distribution box model 1294.2,

modelorder detailspacking unitorder code
1299.12640 064

 

Fonterra-Cylinder lock,
for the Viega-Manifold cabinets,
nickel plated,

modelorder detailspacking unitorder code
1294.9625 245

 
 
 

Fonterra-Room thermostat,
for individual room regulation of the
Fonterra-surface temperature equalization systems,
in connection with Actulating drive model 1248,

modelorder detailspacking unitorder code
 volt  
1243230  610 401

 

Fonterra-Heating/Cooling-room thermostat,
for individual room regulation of
Fonterra-Top-system,
in connection with actuating drive
model 1248,

modelorder detailspacking unitorder code
 volt  
1249.30230  638 450

 

Fonterra-Switsch thermostat,
for individual room regulation of the
Fonterra-surface temperature equalization systems,
in connection with Actulating drive model 1248,

modelorder detailspacking unitorder code
 volt  
1243.3230  616 748

 

Fonterra-Basic unit,
without pump module,
for simple wiring of the
230 V-room thermostates,
for 6 thermostates and 12 heating ciruits,

modelorder detailspacking unitorder code
 volt  
1247230  610 487

 

Fonterra-Basic unit,
with pump module,
for simple wiring of the
230 V-room thermostates,
for 6 thermostates and 12 heating ciruits,

modelorder detailspacking unitorder code
 volt  
1247.3230  613 112

 

Fonterra-Basic unit,
with pump module,
for simple wiring of
230 V-heating/cooling-room thermostat,
for 6 thermostates and 12 heating ciruits,

modelorder detailspacking unitorder code
 volt  
1247.6230  638 467

 

Fonterra-Room thermostat,
for simple wiring of
Fonterra-Surface temperation systems,
in connection with actuating drive
model 1248.1,

modelorder detailspacking unitorder code
 volt  
1243.124  610 418

 

Fonterra-Switch thermostat,
for individual room regulation of the
Fonterra-surface temperature equalization systems,
in connection with actulating drive
model 1248.1,

modelorder detailspacking unitorder code
 volt  
1243.424  616 854

 

Fonterra-Basic unit,
without pump module,
for simple wiring of the
24 V-room thermostates,
for 6 thermostates and 12 heating ciruits,

modelorder detailspacking unitorder code
 volt  
1247.124  610 500

 

Fonterra-Basic unit,
without pump module,
for simple wiring of the
24 V-room thermostates,
for 6 thermostates and 12 heating ciruits,

modelorder detailspacking unitorder code
 volt  
1247.424  615 024

 

Fonterra-Power unit,
for basic unit 24 V,
for power supply of the
basic unit model 1247.1 and model 1247.4,
with safety plug,

modelorder detailspacking unitorder code
 volt  
1247.5230/24  616 731

 

Fonterra-Room thermostat radio controlled,
for individual room regulation of the
Fonterra-surface temperature equalization systems,
in connection with Actulating drive
model 1247.2,

modelorder detailspacking unitorder code
1243.2610 425

 

Fonterra-External radio controlled receiver,
in connection with
radio controlled basic unit model 1247.2,
for increase of
receiving range,

modelorder detailspacking unitorder code
1249.20616 328

 

Fonterra-Actulating drive,
with valve adaptor,
currentless closed,
First open-Function,
function display in cover,
protection type IP 54,
suitable for 360°-installations,

modelorder detailspacking unitorder code
 volt  
1248230  610 524

 

Fonterra-Actulating drive 24 V,
with valve adaptor,
currentless closed,
First open-Function,
function display in cover,
protection type IP 54,
suitable for 360°-installations,

modelorder detailspacking unitorder code
 volt  
1248.124  610 531

 
 
 

Fonterra-Compact control station,
without regulator,
in combination with a boiler control
or a central control unit for
central control of several
heating ciruit manifolds,
up to 15 kW,

modelorder detailspacking unitorder code
1252610 555

 

Fonterra-Compact control station,
with regulator,
with heating/cooling-regulator ECL 301,
for central control of several
heating ciruit manifolds,
up to 15 kW,

modelorder detailspacking unitorder code
1251610 548

 

Fonterra-Manifold control station,
controlled by atmospheric conditions,
with heating regulator ECL 100,
for a weather-depentent regulation
of supply temperature,
in combination with Viega manifold station
model 1004 and model 1006,
up to 10 kW,

modelorder detailspacking unitorder code
1253610 562

 

Fonterra-Manifold regulation station,
preset value,
for a constant regulation of the
feed line temperature,
in combination with Viega-Heating
manifolds model 1004 and model 1006,
up to 10 kW,

modelorder detailspacking unitorder code
1254610 579

 

Fonterra-Room blending station,
for small surface
for max. 2 heating ciruits,
up to 3 kW,
with flow temperature control
and integrated bypass,

modelorder detailspacking unitorder code
1255610 586

 

Fonterra-Double connector 3/4",
for extension room mixing station
for small surface to 2 heating ciruits,

modelorder detailspacking unitorder code
1255.9625 450

 

Fonterra-Multibox Combi-RTL,
for the maximum limitation
of return temperature,
with return temperatur limiter of
e. g. combined floor
radiator heating systems,
return temperature limiter (RTL)
with expansion material filled thermostat,
valve box made of gunmetal,
with euro cone,
with ventilation-/flushing valve,
concealed box with frame,
cover cap and attachment rails,

modelorder detailspacking unitorder code
1472.1639 310

 

Fonterra-Heating controler ECL 100,
for the weather-dependent control of
supply temperature of heating systems,
with pump control,
for wall mounting please use
the socket model 1219.5,

modelorder detailspacking unitorder code
1264610 616

 

Fonterra-Heating/Cooling-controler ECL 301,
electronic temperature control,
in combination with the programm card L32,
programmable for heating
and colling systems,
for wall mounting please use
the socket model 1219.5,

modelorder detailspacking unitorder code
1249.10616 083

Attention:
The programm card L32 is
not included in scope of delivery!
 

Fonterra-Programm card L32,
for ECL 301,
for heating and cooling,
in combination with
controler ECL 301,

modelorder detailspacking unitorder code
1249.109622 046

 

Fonterra-Socket,
for wall mountin ECL 100/301,

modelorder detailspacking unitorder code
1219.5616 885

 

Fonterra-Remote control,
for ECL 100/301,
for individual programming
the week-room temperatures,
with display,
with integrated room temperature sensor
and humidity sensor,
for remote control of
heating/cooling-controller ECL 301,

modelorder detailspacking unitorder code
1249.11616 106

 

Fonterra-External sensor,
for ECL 100/301,
for the weather-dependent control
of panel heatings,

modelorder detailspacking unitorder code
1249.13616 151

 

Fonterra-Analog watch,
for ECL 100,
for a automatic week-programm,
for installation in heating controler model 1264,

modelorder detailspacking unitorder code
1249.14616 199

 

Fonterra-Room temperature sensor,
for ECL 100/301-controler,
for installation in reference room,

modelorder detailspacking unitorder code
1249.15616 229

 

Fonterra-Apply temperature sensor,
for ECL 100/301-controller,
for measuring the heating water temperature,
for installation on piping system,

modelorder detailspacking unitorder code
1249.16616 281

 

Fonterra-Temperature underwater sensor,
for ECL 301,
for limitation of floor temperature
or measuring the heating water temperature,

modelorder detailspacking unitorder code
1249.18616 311

 

Fonterra-Safety temperature limiter,
with concealed temperature adjustment,
for pump circuit at overtemperatures,

modelorder detailspacking unitorder code
1219.6616 892

 
 
 

Press jaw,
for Viega-System pressing tools type 2,
type 3 and Viega-Battery presshandy,

modelorder detailspacking unitorder code
 for press connectors-&durchmesser;  
2799.712  425 302

 

Press jaw,
for PE-Xc- and PB-systems,
for press connectors,
usable with system pressing tools:
type 1, PT2, PT3H, PT3-AH, PT3-EH,
Pressgun 4E and 4B,
battery pressing tool manufacturer
Holger Clasen,
Geberit/Mepla-pressing tool type PWH 75,
type N 230 V type N battery,
Geberit/Mapress-pressing tool type EFP II,
ACO 1, ECO 1, ACO 201, ECO 201, AFP 201,
EFP 201 and Ridgid RP 10-S, RP 10-B,

modelorder detailspacking unitorder code
 for press connector-&durchmesser;  
2299.716/17  351 540
20  351 557
25  351 564

Attention:
Press jaws with dimension 40, 50 and
63 mm are not compatible with
system pressing tool type 1!
 

Press jaw,
for battery pressing tool Picco,
for press connectors of PE-Xc-systems,

modelorder detailspacking unitorder code
 for press connector-&durchmesser;  
2484.712  616 915
14/15  485 559
16/17  485 566
20  485 573
25  485 580

The dimensions up to 20 mm are only suitable for Fonterra.
 

Hand pressing tool,
for press connectors 12 mm,

modelorder detailspacking unitorder code
 for press connectors-&durchmesser;  
278212  401 436

 

Pulling coupling,
for pipe exchange,

modelorder detailspacking unitorder code
 für d  
204212 x 1,3  656 362
14 x 2,0/12 x 1,3  656 379

 

Fonterra-Pipe reel,
for pipe coils
capacity 70 kg,
can be folded or diassembled,

modelorder detailspacking unitorder code
1452562 359

 

Shears,
for PE-Xc-pipes,

modelorder detailspacking unitorder code
 für d  
534112&bindestrichlang;25  652 005

 

Fonterra-Floor pavement additive,
additive for cement screed
(heating screed),
for normal floor pavement,
for the improvement of heat conductivity,
as well as the compression
strength of cement screed,

modelorder detailspacking unitorder code
 kg  
145310  562 717

 

Fonterra-Floor pavement additive,
additive for cement screed
(heating screed),
for thin layered screed with
minimal covering min. 30 mm,

for the improvement of heat conductivity,
as well as the compression strength
of cement screed,

modelorder detailspacking unitorder code
 kg  
145410   562 724

 

Fonterra-Floor pavement additive,
Temporex,
for faster curing and
improvement of floor payment quality,

modelorder detailspacking unitorder code
 kg  
145510  609 207

 

Fonterra-Separating sheet,
separating the layers,
between the EPS and
the butimen surfaces,

modelorder detailspacking unitorder code
 thickness  
12840,1  100,00m²609 887

 

Fonterra-Clamping rail,
self-adhesive,
for safety fiaxtion of
Fonterra-pipes,
2 m long,

modelorder detailspacking unitorder code
 for pipe-&durchmesser;  
127720  20m613 624

 

Fonterra-Clamping rail,
for safety fiaxation of
Fonterra-pipes at on-site insulation,
pipe distance 25 mm,
2 m long,

modelorder detailspacking unitorder code
 for pipe-&durchmesser;  
123415 x 2000  20m613 600
17 x 2000  20m613 617
25 x 2000  20m636 524

 

Fonterra-Plate dowel,
for Fronterra Base-knob panels
without sound insulation,
for connecting the foil elements
with insulation installed on side,

modelorder detailspacking unitorder code
 &durchmesser; x L x &durchmesser;  
148035 x 25 x 5  100569 037

 

Fonterra-Holding needle,
for attaching Viega
surface heating pipes
in the connection area in front
of the manifold
or in knob free spaces,

modelorder detailspacking unitorder code
 L x B  
148150 x 20  500569 044

 

Fonterra-Mounting set,
for fixation of
Viega panel heating pipes,
on steel girder mats,

modelorder detailspacking unitorder code
 for pipe-&durchmesser;  
1272.925  100636 128

 

Fonterra-Ceiling duct,
for BTA,
inlay bos for panel heating pipes
up to 20mm,
for fixation on concrete boarding
for suspending ceilings,

modelorder detailspacking unitorder code
 length x width  
1264.3400 x 60  624 880*
* only available from existing stock

 

PE-Protective tube,
black,
50 m in coils,

modelorder detailspacking unitorder code
 for plastic-pipe
x outside &durchmesser;
  
2004(20) 28  50m110 604

 

Fonterra-Holding strap,
for pipelines,

modelorder detailspacking unitorder code
 length  
1262.41200  100638 344

 
 
 

Fonterra-PE-Xc-pipe,
for the floor heating installation,
oxygen seal
in accordance with DIN 4726,
natural coloured,
240 m in rolls,
modelorder detailspacking unitorder code
 da x s  
140118 x 2,0  240m562 694*
20 x 2,0  240m562 700*
* only available from existing stock

120 m in rolls,
modelorder detailspacking unitorder code
 da x s  
1401.118 x 2,0  120m562 687*
* only available from existing stock

 

Fonterra-Knob plate,
for individual execution of insulation,
without back foaming,
with 33 mm overlapping,
diagonal installation possible,
with place for 16 and 18 mm pipes,
modular dimension: 75 mm,
knob height: 25 mm,
building material class B2,

modelorder detailspacking unitorder code
 length x width  
14301500 x 900  18562 267*
* only available from existing stock

 

Fronterra-Expansion joint profile,
for the secure separation of screed
and support of expansion joints,
elastic PE-core
with 2 cm foam strip,
without coating with adhesive strip,
stable and self-adhesive,
building material class B2
in accordance with DIN 4102,

modelorder detailspacking unitorder code
 length  
14511800  10562 311*
* only available from existing stock

 

Fonterra-Measuring point indicator,
for marking the residual dampness
of measuring points in concrete,

modelorder detailspacking unitorder code
149050569 082

 

Fonterra-Thread connecting piece,
dull nickel-plated,
for unions with euro cone,

modelorder detailspacking unitorder code
 G x G  
1021.51/2 x 3/4  639 877
3/4 x 3/4  639 860

 
 
 

Room thermostat,
white,
for the regulation in a single
room for underfloor heating circuits,
with rotating knob,
with cable 230 V,
protection type IP 30,
control range up to 30 °C,
in connection with model 1465,

modelorder detailspacking unitorder code
1460562 441*
* only available from existing stock

 

Base-control unit,
white,
power strip for the connection
of room thermostats,
with cable for 230 V,
protection type IP 30,
with 6 channels,
in connection with model 1460,

modelorder detailspacking unitorder code
1465562 465*
* only available from existing stock

 

Radio controlled-Room thermostat,
white,
for the regulation of the temperature
in a single room for
underfloor heating circuits,
with rotating knob,
wireless for 230 V,
protection type IP 30,
control range up to 30 °C,
in connection with model 1466,

modelorder detailspacking unitorder code
1461562 458*
* only available from existing stock

 

Radio controlled-Base-control unit,
white,
power strip for the connection of
radio controlled room thermostats,
wireless for 230 V,
protection type IP 30,
with 8 channels,
in connection with model 1461,

modelorder detailspacking unitorder code
1466562 472*
* only available from existing stock

 

Pump relay,
installation ready relay for installation
in the base control unit,
for automatic shutting of the
heating pump, when
heat is not required,

modelorder detailspacking unitorder code
1469562 496*
* only available from existing stock

 

Aerial,
for the external fitting of
the radio controlled basic unit,

modelorder detailspacking unitorder code
1468562 489*
* only available from existing stock

 

Room thermostat covering frame,
white plastic,
for covering larger mortises,

modelorder detailspacking unitorder code
1462white563 011*
* only available from existing stock

 
 
 

Union,
nickel-plated,
for plastic pipe,

modelorder detailspacking unitorder code
 d x R  
102114 x 1/2  10106 041
16 x 1/2  10106 850
17 x 1/2  10113 896
18 x 1/2  10122 270
20 x 1/2  10113 803
20 x 1/2  10120 344

 

Union,
nickel-plated,
for plastic pipe,

modelorder detailspacking unitorder code
 d x R  
1021.114 x 1/2  10112 899
16 x 1/2  10114 923
20 x 1/2  10247 843
20 x 3/4  10136 543

 

Threaded coupling,
nickel plated brass,
for the recommended connection
of oxygen tight Viega-PE-Xc-
Surface heating pipes,

modelorder detailspacking unitorder code
 d  
103017  5117 702
20  5121 143

 

Union,
nickel-plated,
for copper and steel pipe with Euro-cone,

modelorder detailspacking unitorder code
 d  
94385.215  10636 050

 

Coupling,
gunmetal,

modelorder detailspacking unitorder code
 d x d  
271516  10397 463
16 x 12  5446 154*
20  10397 470
20 x 16  5446 161
25  443 641
25 x 16  450 298
25 x 20  450 304